FIRE REGULATIONS
   
The fire regulations for construction products are governed by 2 texts:
Profile elements prior to burning test

FlecheGrise The reaction to fire order of 21 November 2002
FlecheGrise The fire resistance order of 22 March 2004

Profile elements prior to burning test

The following table is an extract of appendix 4 of the reaction to fire order of 21 November 2002 and provides equivalences between the M classification of the French regulation and the Euroclasses (for floor coverings and other products) of the European legislator.

Filet

Classes as per NF EN 13501-1 Requirement

Filet

A1 - - Incombustible
A2 s1 d0 M0
A2 s1 d1 M1
A2 s2/ s3 d0 / d1 M1
B s1 / s2 / s3 d0 / d1 M1
C s1 / s2 / s3 d0 / d1 M2
D s1 / s2 / s3 d0 / d1 M3 (non dripping)
All classes other than E-d2 and F
M4

Filet
Classes as per NF EN 13501-1 Requirement
Filet
A1FL - Incombustible
A2FL s1 M0
A2FL s2 M3
BFL s1 / s2 M3
CFL s1 / s2 M3
DFL s1 / s2 M4